Operating temp.: -40°C to 105 °C
Voltage Grade up to: 60 V DC, 25 V AC (Suitable for 12 V & 24 V system)
Temperature characteristics: 105 °C for 3000 hours , 125 °C for 240 hours, 100 °C for 4 hours (load of 86 gms), -40 °C for 48 hours.
Thermal Overload Capacity: 120 °C for 48 hours.
Electric strength: 1 kV for 30 mins under salt solution
Requirement of oxygen in air to catch fire: more then 29.5%
The temperature required to catch fire (with 21% oxygen): more than 250 °C
Visibility during cable burning: less then 60%
Voltage Grade up to: 60 V DC, 25 V AC (Suitable for 12 V & 24 V system)
Temperature characteristics: 105 °C for 3000 hours , 125 °C for 240 hours, 100 °C for 4 hours (load of 86 gms), -40 °C for 48 hours.
Thermal Overload Capacity: 120 °C for 48 hours.
Electric strength: 1 kV for 30 mins under salt solution
Requirement of oxygen in air to catch fire: more then 29.5%
The temperature required to catch fire (with 21% oxygen): more than 250 °C
Visibility during cable burning: less then 60%
“RADIX’ flexible copper conductor, Insulated FLRY-B AUTO Cable
Nominal Cross-section (sq.mm.) | No. of Strands | Max. Strand Diameter (mm) | Nominal Conductor diameter (mm) | Max. DC Conductor resistance at 20 C (Ω/km) | Minimum Insulation Thickness (mm) | Max. Overall Diameter (mm) | |
Plain Copper | Tinned Copper | ||||||
0.22 | 7 | 0.21 | 0.70 | 77.90 | 84.80 | 0.20 | 1.30 |
0.35 | 12 | 0.21 | 0.90 | 54.40 | 55.50 | 0.20 | 1.40 |
0.50 | 16 | 0.21 | 1.00 | 37.50 | 38.20 | 0.22 | 1.60 |
0.75 | 24 | 0.21 | 1.20 | 24.70 | 25.40 | 0.24 | 1.90 |
1.00 | 32 | 0.21 | 1.35 | 18.50 | 19.10 | 0.24 | 2.10 |
1.25 | 16 | 0.33 | 1.50 | 14.90 | 15.90 | 0.24 | 2.30 |
1.50 | 30 | 0.26 | 1.70 | 12.70 | 13.00 | 0.24 | 2.40 |
2.00 | 30 | 0.31 | 2.00 | 9.42 | 9.69 | 0.28 | 2.80 |
2.50 | 50 | 0.26 | 2.20 | 7.60 | 7.82 | 0.28 | 3.00 |
3.00 | 45 | 0.31 | 2.40 | 6.15 | 6.36 | 0.28 | 3.40 |
4.00 | 56 | 0.31 | 2.75 | 4.71 | 4.85 | 0.32 | 3.70 |
5.00 | 65 | 0.33 | 3.10 | 3.94 | 4.02 | 0.32 | 4.20 |
6.00 | 84 | 0.31 | 3.30 | 3.14 | 3.23 | 0.32 | 4.30 |
- Ultra High-performance flexible cable ensures Durability & long life
- Auto cables are impervious to water, petrol, diesel, acids, engine and lubricating oils, and grease resistant
- suitable for both low and high-temperature applications
- Excellent elctrical & mechanical property
- Compatible with hi-tech harness equipment such as high-speed cutting stripping machines and ultrasonic welding.
- Excellent flame retardant properties
- Standerd packing : 100 m, 200 m, 500 m
- Available colors: Red, Yellow, Blue, Black, Green, Grey, Brown, Orange, Violet, white
CONDUCTOR
99.9% pure electrolytic flexible bare copper conductor as per ASTM B3, DIN EN 13603,
ISO 6722
INSULATION
Pvc Insulation as per DIN 72551 & ISO 6722 Class B
CABLE STANDERD
Generally meets ISO 6722